Nipple into chamber wiggles a bit, what do i do?
- saladtossser
- Sergeant 3
- Posts: 1234
- Joined: Sat Mar 26, 2005 10:40 am
- Location: Toronto
- Contact:
what size? i would use a bolt that will fit in tightly, plug it and epoxy it
"whoa... I thought pimpmann was black..."-pyromanic13
maybe get a longer 1/4" nipple, just put about 6 layers of teflon around it before threading it in and it shouldn't wiggle unless you tapped it wrong...
Why wouldn't you use the street side of the elbow to go into the chamber and the nipples to go from the female side of the elbow into the ball valve?
Why wouldn't you use the street side of the elbow to go into the chamber and the nipples to go from the female side of the elbow into the ball valve?
-FrOgY-
I wish people would stop needing a better signature!
I wish people would stop needing a better signature!
Is this a result of tapping with the fitting? If so I dont feel sorry for you and get a damn pipe tap... Even worse you proably tapped it with the teflon on... It could also be a possible result of whatever you connected into there wasnt fastened down then flopped around and weakend the friction fit. I would say to tap a 3/8" plug into the same hole, and re-tap the right way the hole for whatever your threading in.
rmich732, thanks for your 3-word ALL CAPS input, NOT!
rmich732, thanks for your 3-word ALL CAPS input, NOT!
Did you use a tap or force the fitting into the pipe? If you did use a tap, did you drill the correct size hole?
Either way, go get a bigger tap (like 3/8) and drill and tap a bigger hole. Then thread the 1/4 fitting into a bushing to fit into the new hole and thread this whole thing in.
Either way, go get a bigger tap (like 3/8) and drill and tap a bigger hole. Then thread the 1/4 fitting into a bushing to fit into the new hole and thread this whole thing in.
- carlbelcher
- Corporal
- Posts: 532
- Joined: Mon Jun 12, 2006 6:54 pm
I you were using a 1/4" NPT tap you should have used a 7/16" drill bit not a 3/8" that's probably your problem. I would drill a 45/64" hole and tap it for 1/2" NPT and get a 1/2" NPT to 1/4" NPT bushing.
Is your Google.com Broken?!
- SpudStuff
- Sergeant 5
- Posts: 1410
- Joined: Sat Dec 10, 2005 3:55 pm
- Location: Cupertino, California
- Contact:
a 3/8 hole is smaller than a 7/16 so that dosn't cause a prob. i always use a 3/8 when tapping 1/4 inch ntp
get yellow(thick) teflon tape, for gas line, give it 6 or7 rapps and turn it in. the other prob is you could have tapped into the plastic too far becuse the NTP is taperd
get yellow(thick) teflon tape, for gas line, give it 6 or7 rapps and turn it in. the other prob is you could have tapped into the plastic too far becuse the NTP is taperd
- carlbelcher
- Corporal
- Posts: 532
- Joined: Mon Jun 12, 2006 6:54 pm
I would still consider drilling the hole out and re-tapping. PVC threads are weak enough as it is without being over-sized. But then again I don't even like to tap into PVC.
Is your Google.com Broken?!
what most probably must of happened then is i didnt drill perfectly straight i must have leaned into it a bit and made a weird hole, o well it happens.
By the way i went to home depot and the 7/16 drill bit is ..huge... a slight mistake and the hole is ruined...
By the way i went to home depot and the 7/16 drill bit is ..huge... a slight mistake and the hole is ruined...