Sprinkler valves keep leaking...

A place for general potato gun questions and discussions.
User avatar
Mihlrad
Specialist 4
Specialist 4
Posts: 467
Joined: Tue May 23, 2006 6:45 pm

Tue Jun 13, 2006 9:29 am

Ok well.. so far ive gone through 2 sprinkler valves im not sure if i should do a third or just get a ball valve... the cost is adding up on them so... What happened the first time is i tried to hand thread it...bad idea... second time for some reason the hose adapter i used to thread it with a drill... wasnt making threads it jus made a smooth hole about 1/3 of the way till i tried a different one which made a nice leak for the blowgun. Also on the second one, it randomly began to leak air out of the sides of the valve... like where the 2 pieces of it come together. Should i just try it once more or just use a ball valve?
User avatar
frogy
Corporal 2
Corporal 2
Posts: 603
Joined: Mon May 29, 2006 1:24 pm
Location: Ohio

Tue Jun 13, 2006 10:10 am

It sounds like you have absolutely no idea how to tap a thread....

buy a thread tap and buy new top covers for your valves, they're not ruined... Use teflon tape around your fitting and make sure there's no PVC shavings inside of your valve because that causes it to leak...
-FrOgY-

I wish people would stop needing a better signature!
User avatar
Mihlrad
Specialist 4
Specialist 4
Posts: 467
Joined: Tue May 23, 2006 6:45 pm

Tue Jun 13, 2006 10:48 am

where can i buy new tops... havent seen those sold anywhere in my life...
spudshot
Sergeant
Sergeant
Posts: 1036
Joined: Sun Oct 03, 2004 7:16 am

Tue Jun 13, 2006 10:50 am

Just about any hardware store should have them. You need a 1/4" NPT tap and a 7/16" drill bit. it needs to say NPT, thats is national pipe thread, and its much different than NC or NF (national coarse or national fine)
Image
User avatar
Mihlrad
Specialist 4
Specialist 4
Posts: 467
Joined: Tue May 23, 2006 6:45 pm

Tue Jun 13, 2006 12:55 pm

I used a 1/4 inch hose adapter like it says in the guide...
spudshot
Sergeant
Sergeant
Posts: 1036
Joined: Sun Oct 03, 2004 7:16 am

Tue Jun 13, 2006 6:06 pm

yea, thats the cheap ass way of doing it, you need a tap and a 7/16" drill bit
Image
User avatar
huse_spud
Specialist 2
Specialist 2
Posts: 269
Joined: Sat Apr 15, 2006 6:52 pm
Location: Center Junction, IA

Tue Jun 13, 2006 8:05 pm

it sounds like taps are pretty expensive, but idk.

maybe mihlrad spun the hose adapter too fast or had too big of a hole.

when you put the hose adapter in the drill, you just press down into the pre-drilled hole on the valve lid and slowly turn the drill chuck right?

and it sounds like doing it by hand creates leaks hmmm.
spudshot
Sergeant
Sergeant
Posts: 1036
Joined: Sun Oct 03, 2004 7:16 am

Tue Jun 13, 2006 8:29 pm

taps those size are about 5 bucks, its the bigger sizes that really kill you.
Image
User avatar
huse_spud
Specialist 2
Specialist 2
Posts: 269
Joined: Sat Apr 15, 2006 6:52 pm
Location: Center Junction, IA

Tue Jun 13, 2006 9:27 pm

$5 not bad, not bad at all thanks bud.

what size? 7/16 you said?
User avatar
frogy
Corporal 2
Corporal 2
Posts: 603
Joined: Mon May 29, 2006 1:24 pm
Location: Ohio

Tue Jun 13, 2006 9:29 pm

7/16 drill bit, and a 1/4 NPT tap (they're about 1/2" diameter)
-FrOgY-

I wish people would stop needing a better signature!
Post Reply