Just a little thing that has been nagging at me...
-
- Private 4
- Posts: 84
- Joined: Sat Mar 17, 2007 9:43 pm
- Location: Philly, PA. (home's in Worcester,MA)
I use pipe from Charlotte pipe, which is very good quality pipe. I also use fittings from Lasco, also exceptional quality. Now, every person who has warned people from not using dwv parts has mentioned that your fittings should have a psi rating on them. Not so here. Why?
what sort of things would you look for in the design? i know to look for how far a pipe will slide into the fitting, is there anything else?It's hard to find fittings with pressure ratings. Sometimes you can tell by their design if they are meant for DWV applications though.
-
- Private 4
- Posts: 84
- Joined: Sat Mar 17, 2007 9:43 pm
- Location: Philly, PA. (home's in Worcester,MA)
Obviously, I know to use pressure rated parts. all Lasco parts have the astm and nsf ratings on them. I was just curious whether they should have an actual psi rating or not.
- subterranean
- Specialist
- Posts: 171
- Joined: Sat Oct 21, 2006 11:39 am
- Location: columbus, ohio
"NSF-PW" is pressure rated. The guy at my local plumbing supplier sold me a peice that said NSF-61,he says will hold high pressures. so any fittongs with those markings on them are good choices. NSF-dwv is to be avoided.
- subterranean
- Specialist
- Posts: 171
- Joined: Sat Oct 21, 2006 11:39 am
- Location: columbus, ohio
well thats not all true, when it comes to pipe, yes some pipe labled nsf-dwv will also has a pressure rating printed on it. If you look closly, a little farther down the pipe there will be an nsf-pw marking as well.(this pipe is made for both pressure and drainage applications) when it comes to fittings, nsf-dwv is NOT the same as nsf-pw, it is made differently and should not be asumed as "ok" for a pneumatic. only if you decide to keep the pressure below 80psi, dont use nsf-dwv fittings.
- frankrede
- Sergeant Major 2
- Posts: 3220
- Joined: Thu Jul 20, 2006 9:47 pm
- Has thanked: 1 time
- Been thanked: 1 time
Now was that directed towards me?subterranean wrote:well thats not all true, when it comes to pipe, yes some pipe labled nsf-dwv will also has a pressure rating printed on it. If you look closly, a little farther down the pipe there will be an nsf-pw marking as well.(this pipe is made for both pressure and drainage applications) when it comes to fittings, nsf-dwv is NOT the same as nsf-pw, it is made differently and should not be asumed as "ok" for a pneumatic. only if you decide to keep the pressure below 80psi, dont use nsf-dwv fittings.
Current project: Afghanistan deployment
- subterranean
- Specialist
- Posts: 171
- Joined: Sat Oct 21, 2006 11:39 am
- Location: columbus, ohio
not really, it was just a response to your reply. I wanted to help clarify what you were talking about, so the person who created this thread would understand it better.
-
- Private 4
- Posts: 84
- Joined: Sat Mar 17, 2007 9:43 pm
- Location: Philly, PA. (home's in Worcester,MA)
Despite what persona I may have created thus far, I am not an idiot. I have stated time and again that I understand the National Sanitation Foundation's markings. The question was a simple bout of curiosity as to whether my fittings should be marked with a rating of specific Pounds per Square Inch.
benstern has already answered this curiosity-induced question. Thank You.
benstern has already answered this curiosity-induced question. Thank You.