Sprinkler valve question for whole house water valve.

Meaningful discussion outside of the potato gun realm. Projects, theories, current events. Non-productive discussion will be locked.
User avatar
boyntonstu
Sergeant
Sergeant
Posts: 1039
Joined: Sun Jun 28, 2009 8:59 am

Wed Jul 28, 2010 9:34 am

I am going to place a NC sprinkler valve in series with my main house ball valve.


How do I open the valve if we get a power outage?
User avatar
Technician1002
Captain
Captain
Posts: 5189
Joined: Sat Apr 04, 2009 11:10 am

Wed Jul 28, 2010 10:08 am

maybe batteries.. A computer UPS could do the job.
User avatar
boyntonstu
Sergeant
Sergeant
Posts: 1039
Joined: Sun Jun 28, 2009 8:59 am

Wed Jul 28, 2010 10:18 am

Technician1002 wrote:maybe batteries.. A computer UPS could do the job.
I was hoping for a physical opening.

Another method is to parallel the main water valve that is normally closed when power can be supplied to the SV.
User avatar
POLAND_SPUD
Captain
Captain
Posts: 5402
Joined: Sat Oct 13, 2007 4:43 pm
Been thanked: 1 time

Wed Jul 28, 2010 10:50 am

I am going to place a NC sprinkler valve in series with my main house ball valve
no offence but it sounds a bit stupid... why do you need a sprinkler valve in the first place ?
Children are the future

unless we stop them now
User avatar
Gippeto
First Sergeant 3
First Sergeant 3
Venezuela
Posts: 2504
Joined: Sat Jan 19, 2008 10:14 am
Location: Soon to be socialist shit hole.
Has thanked: 2 times
Been thanked: 17 times

Donating Members

Wed Jul 28, 2010 11:37 am

POLAND_SPUD wrote:
I am going to place a NC sprinkler valve in series with my main house ball valve
no offence but it sounds a bit stupid... why do you need a sprinkler valve in the first place ?
X2....What's the point Stu?

If you want a redundant valve with manual control, why not just use another ball valve?
"It could be that the purpose of your life is to serve as a warning to others" – unknown

Liberalism is a mental disorder, reality is it's cure.
User avatar
jor2daje
Specialist 4
Specialist 4
Posts: 418
Joined: Sun Oct 05, 2008 9:41 pm
Location: Southern California

Wed Jul 28, 2010 12:20 pm

most sprinkler valves that I have used have a small plastic lever below the solenoid so that you can open the valve manually. If not a powerful magnet stuck on top of the solenoid should open it and leave it open.

And I'm assuming its for watersaving device so you can shut of all the water to your house from a switch inside. But manually override if the power goes out.

Image that little black lever
Patience is a virtue, get it if you can, seldom in a women, never in a man.
User avatar
boyntonstu
Sergeant
Sergeant
Posts: 1039
Joined: Sun Jun 28, 2009 8:59 am

Wed Jul 28, 2010 3:38 pm

jor2daje wrote:most sprinkler valves that I have used have a small plastic lever below the solenoid so that you can open the valve manually. If not a powerful magnet stuck on top of the solenoid should open it and leave it open.

And I'm assuming its for watersaving device so you can shut of all the water to your house from a switch inside. But manually override if the power goes out.

Image that little black lever
You are close.

I want the water on only if there is a person up and about in the toilet, kitchen or laundry room.
User avatar
jor2daje
Specialist 4
Specialist 4
Posts: 418
Joined: Sun Oct 05, 2008 9:41 pm
Location: Southern California

Wed Jul 28, 2010 4:01 pm

I dont see why it wouldnt work, but I think you will need a much larger sprinkler valve so you have enough flow for your whole house.
Patience is a virtue, get it if you can, seldom in a women, never in a man.
User avatar
POLAND_SPUD
Captain
Captain
Posts: 5402
Joined: Sat Oct 13, 2007 4:43 pm
Been thanked: 1 time

Wed Jul 28, 2010 6:06 pm

I want the water on only if there is a person up and about in the toilet, kitchen or laundry room.
sorry but I still don't get it... what's the point of it ? it's not that you are saving anything
Children are the future

unless we stop them now
User avatar
boyntonstu
Sergeant
Sergeant
Posts: 1039
Joined: Sun Jun 28, 2009 8:59 am

Wed Jul 28, 2010 6:19 pm

jor2daje wrote:I dont see why it wouldnt work, but I think you will need a much larger sprinkler valve so you have enough flow for your whole house.
My house supply is 3/4" PVC.

Would a 3/4" straight though sprinkler valve be equal to that?
User avatar
jimmy101
Sergeant Major 2
Sergeant Major 2
United States of America
Posts: 3206
Joined: Wed Mar 28, 2007 9:48 am
Location: Greenwood, Indiana
Has thanked: 6 times
Been thanked: 18 times
Contact:

Wed Jul 28, 2010 6:56 pm

boyntonstu wrote:
jor2daje wrote:I dont see why it wouldnt work, but I think you will need a much larger sprinkler valve so you have enough flow for your whole house.
My house supply is 3/4" PVC.

Would a 3/4" straight though sprinkler valve be equal to that?
Roughly yes. A 1" might be a bit better though.

Those valves typically operate on 12V or 24V (sometimes AC, sometimes DC). In a power outage the vent screw can be used, though it might dribble water. A 9V battery will operate the valve without any problems, though I don't know how long a 9V battery would be able to operate the valve. A small 12V lead-acid gel battery, with it's own 120VAC charger, would probably be able to operate the valve for a couple days.

Image
User avatar
Gippeto
First Sergeant 3
First Sergeant 3
Venezuela
Posts: 2504
Joined: Sat Jan 19, 2008 10:14 am
Location: Soon to be socialist shit hole.
Has thanked: 2 times
Been thanked: 17 times

Donating Members

Thu Jul 29, 2010 12:01 am

POLAND_SPUD wrote:
I want the water on only if there is a person up and about in the toilet, kitchen or laundry room.
sorry but I still don't get it... what's the point of it ? it's not that you are saving anything
Maybe his toilet leaks and he doesn't know how to fix it? :wink:
"It could be that the purpose of your life is to serve as a warning to others" – unknown

Liberalism is a mental disorder, reality is it's cure.
User avatar
boyntonstu
Sergeant
Sergeant
Posts: 1039
Joined: Sun Jun 28, 2009 8:59 am

Wed Aug 18, 2010 8:23 am

jor2daje wrote:most sprinkler valves that I have used have a small plastic lever below the solenoid so that you can open the valve manually. If not a powerful magnet stuck on top of the solenoid should open it and leave it open.

And I'm assuming its for watersaving device so you can shut of all the water to your house from a switch inside. But manually override if the power goes out.

Image that little black lever
I have the same valve.

What happens if the diaphragm breaks?


Will water go through or will it leak externally?
User avatar
qwerty
Corporal 2
Corporal 2
Posts: 678
Joined: Sun Apr 12, 2009 2:16 am

Wed Aug 18, 2010 10:26 am

i doubt it would break as it's rubber but if it does i'm guessing the water woulf just go through. But again, what's the point? a ball valve would be fine and after repeated use the diaphragm might give out.
I visit occasionally to make unrelated posts.
User avatar
velocity3x
Corporal 4
Corporal 4
Posts: 828
Joined: Fri Jun 05, 2009 3:09 pm
Location: Yuma, Arizona
Contact:

Wed Aug 18, 2010 12:09 pm

boyntonstu wrote:I am going to place a NC sprinkler valve in series with my main house ball valve.
This is substantially less than a good idea. What would you do if you have a house fire that you could quickly and easily manage if you have water but, the Sprinkler valve for whatever reason, refuses to open?